Hospital Autoclave Sterilizer Machine
CM 1624 BASIC
-
Unit has steam pressure vessel and protection spread in
hardened steel.
- Wellbeing gadgets: Safety valve, weight valve.
-
Standard highlights: Steam discharge valve, pressure
measure, water outlet, treated steel inward stand,
silicone gasket.
- Force Supply: 230 V, 1 Phase, 50 Hz AC Supply.
- Working weight: 15 psi.
- Temperature: 121 and degree Celsius
HORIZONTAL HIGH PRESSURE STERILIZER
- Carries CE Mark
-
End ring hydraulically formed without joints to sustain required pressure. All other joints Argon Arc Welded.
-
Unique Multiport valves located at the top controls all operations manually.
-
Two safety valves spring loaded and a pressure switch provided to prevent accidental pressure build up.
-
Works on 121°C at 17 psi(1.05 kgf/cm2 to 1.2 kgf/cm2)
-
Low water level protection for heaters.
-
Pressure lock device for the door.
- Hydrostatically tested 2 times the working pressure.
- Vacuum system incorporated through Multiport valve makes linen dry.
- Power : 9 KW. 440 V, 3-Phase.
- First Cycle : 90 minutes.
- Subsequent : 40 minutes.
HORIZONTAL HIGH SPEED STERILIZER
- Carries CE Mark
-
End ring hydraulically formed without joints to sustain required pressure. All other joints Argon Arc Welded.
-
Unique Multiport valves located at the top controls all operations manually.
-
Two safety valves spring loaded and a pressure switch provided to prevent accidental pressure build up.
- Works on 134°C at 32 psi(2.1 kgf/cm2)
-
Low water level protection for heaters.
-
Pressure lock device for the door.
- Hydrostatically tested 2 times the working pressure.
- Best suited for rapid sterilization of instruments for Cardiac, Ortho, Neuro & Urology.
- Instruments come out dry after the cycle.
- Power : 18 KW. 440V, 3-Phase.
- First Cycle : 35 minutes, 20 minutes preheating time 15 minutes actual time.
- Subsequent : 09 minutes
HORIZONTAL HIGH PRESSURE STEAM CUM ETO STERILIZER
- Carries CE Mark
-
End ring hydraulically formed without joints to sustain required pressure. All other joints Argon Arc Welded.
-
Unique combination of Steam cum ETO Sterilizer. Economical solution when the Hospital needs Steam Sterilizer along with ETO sterilizer.
-
Required Water Ring Vacuum Pump and ETO Cylinder is Included in the package.
- Available in both HPS-11 and HSS-12 models.
-
Model HPSET 14 - HPSET 14A
ETO STERILIZER
-
Cycle advances consequently through vacuum, exposure,
disinfecting, and circulating air through stages which
held in memory regardless of whether a force blackout
happens.
-
Screen on the control board show explicit stages during
the activity
-
A break test work takes a prevision of any spillage
probability and the sterilizer can be begun just when the
vacuum is totally drawn.
-
Utilize singular gas canister of 100% ethylene oxide. It
wipes out likely spillage from tanks or fittings.
-
Negative chamber pressure guarantees that gas can’t escape
into working zone.
-
There is no arrival of E.O gas until penetrating happens
inside the sterilizer and simply after the entryway is
bolted and a total vacuum is drawn.